Technical Chart
Model | Chamber Size | Overall Size | Steam | Water | Power |
W*H*D mm | W*H*D mm | Kg/cycle | Kg/cycle | KVA | |
MDB-0.11V | 400*400*700 | 1000*1800*1040 | 14 | 15 | 2 |
MDB-0.16V | 400*400*1000 | 1000*1800*1340 | 16 | 20 | 2 |
MDB-0.20V | 400*400*1300 | 1000*1800*1640 | 18 | 25 | 2 |
MDB-0.24V | 600*600*670 | 1200*2000*1010 | 20 | 30 | 2 |
MDB-0.30V | 600*600*840 | 1200*2000*1180 | 22 | 35 | 2 |
MDB-0.36V | 600*600*1000 | 1200*2000*1340 | 25 | 40 | 2 |
MDB-0.45V | 600*600*1250 | 1200*2000*1590 | 27 | 50 | 2 |
MDB-0.60V | 600*600*1670 | 1200*2000*2010 | 30 | 60 | 3 |
Autoclave Piping And Components
Specifically designed for use with steam systems that demand the highest safety conditions. 316L grade stainless steel is used for the chamber, piping and fittings. The inner chamber walls have a mirror like polished finish (Ra < 10μm) to create a smooth surface.
The chamber drain valve area is the coldest spot in the chamber. The BSL autoclaves resolve this problem by applying steam directly to the chamber drain valve area.
The hot-well is a stainless steel water reservoir in which the feed water is heated to 80-90°C prior to entering the steam generator. The hot-well facilitates the removal of non-condensable gases out of water.
Safety Valve
A safety valve is fitted to the chamber. Steam blasts from the safety valve are captured and condensed in an expansion vessel (optional) and then decontaminated before discharge to drain. Any remaining gases are treated via a microbiological sanitary air filter (optional).
Diaphragm Valves
Separate diaphragm valves (optional) for steam to the jacket and chamber prevent contamination from entering the valve mechanism.
Tri-Clamp Fittings
Tri-clamp fittings provide uniformly smooth and crevicefree self-aligning joints for non-contaminating steam flows. They minimise the possibility of external contamination penetration through the valves and piping connection areas.
Biological Seal
The bio-shield is a barrier whose purpose is to create a complete hermetic seal between the differently qualified zones, providing maximum biological containment between the zones. The bio-shield system meets BSL3 and BSL4 bio-safety levels using a combination of stainless steel plates and flexible neoprene wall seal to prevent micro-organisms from passing between zones.
Jacket Frame
A fully welded metal flange with threaded studs surrounds the jacket. A counter plate is attached to the flange using the nuts provided. Any necessary fittings for electrical connections pass through this section of the bio-shield via specially sealed conduits.
Wall Frame
A wall frame is built into the concrete wall of the building. Continuous neoprene sealing is used to seal the sterilizer completely in the aperture in the wall.
ZHANGJIAGANG MEDPHARM MACHINERY LTD.
MEDPHARM Company team is committed to providing quality sterilization products, service, parts and
maintenance training at significant savings. From customized parts packages to turnkey equipment
acquisition and installation, our innovative sterilization solutions are designed to meet our customers' needs.
We understand that untimely breakdowns are costly and can be detrimental to your everyday operations.
Our service team is compromised of expert technicians that respond quickly to all of your service needs.
We offer on-site service support including inservices, installation and deinstallation of your equipment. From
breakdown repairs to comprehensive maintenance programs, we have an innovative service solution for you.
We will service on-Site Repairs.Our staff is equipped with the resources required to provide you with
on-site, on-time repairs in compliance with manufacturer specifications. We also provide installation,
deinstallation, and inservices on most makes and models of sterilization equipment. Near or far we can
provide you with service support that you need.
Our reconditioning background has taught us of the importance of having quality parts on hand at all times.
We have a large inventory of individual repair parts, as well as preventive maintenance kits, and consumables
in stock and ready to ship today.
With our expert technical support staff, it is not always necessary to have part numbers to place an order.
We will help you identify the quality parts that you need.