10 Million Operating Times Car Parking Drivewany Barrier Gates With Stainless Steel
Why choose us?
1. OEM Brand, Logo, Label available
2. 1 Year Standard Warranty, excellent after-sales service
3. 24h*7 days at your service to give you best support
4. Detailed installation manual and wiring diagram to make
everything be easy
5. Fast finishing time for you to become more competitive at your
local market :3-5 days for small order.
Specifications
Model | DZ-V |
Working Temperature | -35℃~+65℃ |
Voltage | 220V±10%, 110V±10%, 50/60HZ |
Rated power | 400W |
Relative humidity | ≤90% |
Remote control distance | ≥30m, ≤100m (open sunny weather) |
Net weight | 50kgs |
Speed | 0.6S-6S |
Boom Length | 2.5 meters |
Motor No-load Speed | 3000r/min |
Protection Degree | IP44 |
Functions
* Open and close speed adjustable.
* Arm direction left and right can change easily
* When power off, manual open and close arm, and lock itself.
* 24V battery input port
* Delay close arm function (1s-300s, adjustable)
Communication with customers
1) Q: Connected power and press open/close button but traffic
barrier gate no action?
A | Reason | Solution |
1 | Fuse blown | Check fuse and power in controller |
2 | Battery of remote control powered off | Change a new one |
3 | External protection circuit break or at protecting status | Open the barrier door and click OPEN/CLOSE button on control box |
4 | Same frequency interference | Check photocell and loop detector |
2) Q:Connected power and press open/close button,traffic barrier
gate will move but even when it is at right position, the motor
still running and not stop?
A | Reason | Solution |
1 | Limit switch | Adjust the horizontal/vertical limit switch to correct position |
2 | Main controller failure | Change a new one |
3) Q: Motor running but traffic barrier gate arm no action?
A | Reason | Solution |
1 | Barrier arm at 45° position where is hard to move | Unlock clutch and manually rotate arm to horizontal or vertical position then try again |
2 | Tension of balancing spring not suitable | Adjust spring exactly |
3 | Low working voltage | Check the voltage and power |
4) Q: When opening/closing,traffic barrier gate arm cannot reach
right position (90° vertical & 180° horizontal)?
A. | Reason | Solution |
1 | Length adjustment of connecting rod not correct | Open barrier door and unlock clutch to check when arm at 90° vertical position if the master rod covers slave one; when arm at 180° horizontal position if master rod and slave one are in the same straight line |
2 | Nuts on the limit switch loose | Tighten the nuts when arm at 90° vertical and 180° horizontal |
For the things that most customer want to know:
1. One year's free servicing is supplied( not including the arm)
2. Lifetiom charged servicing is offered.
3. Technology servicing is supplied
The following situations are charged for servicing (or changing):
1. Broken by wrong installation.
2 Broken by improper voltae.
3. The surfaces of the system destroyed by wrong installation our
use.
4. Broken by natural disaster.
5. Overdue
6. Servicing items out of our promises.
The upgrade and improvement of the product won't be notified if
there is any.
The explaining authority of this product instruction and service
article belong to the production factory.
Contact information:
Sue Zhang
Skype:SueZhang729
Whatsapp:+86 158 7925 9831
Email:sue@wonsunbarrier.com
Shenzhen Wonsun Machinery & Electrical Technology Co. Ltd
![]() |