PMC72S meter is a multi-functional power monitoring meter, it
combines function of collecting data and control, and it can
replace many kind of meters, relays, transformers and others
components. PMC72S can be installed in different positions of
electricity distribution system.
PMC72S is designed with RS-485 communication interface, which
enable itself to be integrated into a variety of power monitoring
systems. Data acquisition and remote control can be easily
performed through the supporting management software or other
industrial configuration software.
PMC72S is a true RMS-based measuring meter that can accurately
measure highly nonlinear loads. Its advanced grid frequency
synchronization sampling technology enables it to accurately
measure a variety of power parameters, including voltage/current
RMS, frequency, active power, reactive power, apparent power, power
factor, input/output active energy, total active energy,
Input/output reactive power, total reactive power, apparent power,
voltage total harmonic distortion (THD), 1~31 voltage harmonics,
current total harmonic distortion (THD) and 1~31 current harmonics,
etc. . All measurement values, min value and max value, and demand
measurement values can be viewed on the screen display or be
checked via remotely software control.
Overview of Meter functions
Table 1
Host Device’s functions and characteristics |
Transient true RMS value |
Current Each single phase and combined phase, average value |
Phase voltage/Line voltage Each single phase and combined phase, average value |
Frequency 45~65Hz |
Max/Min VALUE |
Max/Min CURRENT RMS |
Max/MinVOLTAGE RMS |
Max/Min Frequency |
Max/Min THD I and THD U |
Demand and peak value |
Current per phase the present value/peak value/monthly peak value |
Power quality |
(THD) current and voltage |
1-31times harmonic analysis current and voltage |
Voltage crest factor CF and current K factor |
Event record |
100pcs SOE event record |
Alarm system |
8 warning channels with configurable limit value |
4 warning channels with configurable logic |
Communication |
RS-485 /MODBUS-RTU Protocol |
Display |
Large screen STN liquid display |
Real time clock |
Year, month, date, minute, second |
Others |
Support program online upgrade |
Table 2
Auxiliary module features |
DI input module (optional) |
2-channel DI input (Dry Contact) |
Relay (DO) output module (optional) |
1-channel relay output, which can be set by local over-limit alarm or by remote control |
Analog input (AI)/output (AO) module (optional) |
1 Channel only Being optional for 4-20mA DC analog input, 0-5V DC analog input, 4-20mA DC analog output |
Technical Parameters:
Electrical characteristics | ||
Measure Type | 3P3W ACsystem,3P4W ACsystem | |
Sampling rate | 128 points per cycle | |
Data refresh rate | 1S | |
Measure accuracy | Current | ±0.2%FS |
Voltage | ±0.2%FS | |
Power | 0.5S | |
Frequency | ±0.001Hz | |
DC input (AI) | 0.5% FS | |
DC output (AO) | 0.5% FS | |
Input voltage characteristics | Measure Voltage | 3 *220/380V(Directly input) |
3 * 57.7/100V(PT secondary side) | ||
Allowed overload capability | 1.2 times/continuous | |
Input resistance | 300KΩ/phase | |
Input current characteristics | Measure current | 5A (CT Secondary side)Or 1A (CT Secondary side) |
Allowed Overload capability | 1.2 times/continuous | |
Input resistance | <0.1Ω | |
Binary input | Working valtage | 15 VDC |
Input resistance | 12KΩ | |
Isolation valtage | 2KV | |
Relay Output | Node type | Mechanical contact |
Node capability | 220 VAC/5A,30 VDC/5A | |
4-20mA DC input measurement | Measure current | 4-20mA |
Allowed Overload capability | 1.2 times/continuous | |
Input resistance | 10Ω | |
Isolation voltage | 2KV | |
0-5V DC input measurement | Measure voltage | 0-5V |
Allowed Overload capability | 1.2 times/continuous | |
Input resistance | 12.5KΩ | |
Isolation voltage | 2KV | |
4-20mA DC output | Open-circuit | 15VDC |
Load capability | ≤600Ω | |
Isolation voltage | 2KV | |
Power supply | AC | 85~264 VAC/45-65Hz |
DC | 100~375 VDC | |
Power consumption | < 3W | |
Mechanical performance | ||
weight | <0.5kg | |
IP protection Level | Meter Panel IP52 Meter Host IP30 | |
Dimension | Host | 75 X 75 X 113 mm |
Working temperature | Display screen | -20~70℃ |
Meter | -25~70℃ | |
Storage temperature | Meter+display screen | -40~85℃ |
Relative humidity | 5% - 90%RH,No condensation | |
EMC | ||
Antistatic discharge interference | IEC 61000-4-2,Level 4 | |
Anti-fast transient group pulse | IEC 61000-4-4,Level 4 | |
Anti-surg | IEC 61000-4-5,Level 3 | |
Resistance to power frequency magnetic field | IEC 61000-4-8,Level 3 | |
Electrical insulation performance | ||
Insulation resistence | GB/T13729,>50MΩ | |
Power frequency withstand | GB/T13729,AC 3KV 50Hz /1min | |
Impulse voltage | GB/T13729,5KV,1.2/50us |
PMC72S Guide for selection of power parameter measurement and control instrument
Model specification:PMC72S-①-②-③-④-⑤ | |
① Model code: | |
1 | 57.7/100V Rated measurement voltage,5A Rated measurement current. |
2 | 57.7/100V Rated measurement voltage,1A Rated measurement current. |
3 | 220/380V Rated measurement voltage,5A Rated measurement current. |
4 | 220/380V Rated measurement voltage,1A Rated measurement current. |
② Model code: | |
1 | Power supply:85~264 VAC/45-65Hz,100~300 VDC |
③ Model code: | |
0 | Without DI |
2 | 2 Channels DI |
④ Model code: | |
0 | Without relay output |
1 | Optional 1 Channel relay output |
⑤ Model code: | |
ab | ab is a 2 integer,a means AI01 port optional for AI/AO modules,b
means AI02 port optional for AI/AO 0–none 1 -0-5VDCanaloginputmeasure(AI) 2 -4-20mA DC analog input measure(AI) 3 -4-20mA DC analog output(AO)For example:ab=00,Means AI01 port is not equipped with AI/AO module,AI02 port is not equipped with AI/AOmodule ab =01,Means options 0-5V DC analog input measure; |
For example:Order model:PMC72S-3-1-2-1-02
Means PMC72S rated measure 220/380V,5A;working power supply as 85~264 VAC/45-65Hz;optional with 2channels binary input(DI);1channels relay output;1channel 4-20mA DC analog input measure (AI01 port),1 channel
4-20mA DC analog input measure(AI02 port)
Kingsine Electric Automation Co., Ltd.
Who am I ?
Since its establishment in 1999, Kingsine Electric Automation Co., Ltd. has focused on researching and developing, producing, and selling Protection Relay Test Sets, CT Analyzers, Reference Power Sources and Calibrators, Voltage and Current Amplifiers, Electricity Monitoring Systems, and Instrumentation. To date, Kingsine's products have been recognized by customers in more than 80 countries worldwide. We regularly participate in large-scale power and energy exhibitions worldwide, including in the United States, Italy, France, Poland, Australia, Dubai, Turkey, Brazil, Philippines, Malaysia, Indonesia, South Africa, Egypt, and other countries, and have received widespread acclaim.Our protection relay testing equipment is compatible with world-renowned relay protection devices such as ABB, SIEMENS, ALSTOM, MITSUBISHI, Schneider, AREVA, SEL, GE, and others. Kingsine Electric has also established a distribution network with partners in the Americas, Europe, Asia, the Middle East, and other countries to provide comprehensive services.
Kingsine is a core supplier to China's State Grid
The facts demonstrate that China's annual power generation has remained the world's number one, with a projected power generation of 840 billion kilowatt hours in 2022, compared to the United States' projected 430 billion kilowatt hours in the same year. China has built the world's most advanced power transmission system for DC current at 1100KV ultra-high voltage levels and more than 11,000 digitized substations based on the IEC61850 standard. China's power grid has the largest, most advanced, safest and most stable power system in the world. We are honored to be the core supplier for State Grid Corporation of China.
Where did I come from?
Kingsine Electric is located in Shenzhen, the "Innovation Capital of China". We have also established subsidiaries in Canada and Hong Kong. Shenzhen is a benchmark city for the development of China's high-tech industry and is home to leading Chinese companies in various industries. Many of China's top companies, including Huawei, the world's largest communication company; DJI, the world's largest commercial drone company; BYD, the world's largest electric vehicle company (which sold 1.86 million electric vehicles globally in 2022, surpassing Tesla's sales of 1.37 million); and Tencent, one of China's leading internet companies, are based in Shenzhen. Excellent enterprises can influence each other, and as the world's factory, Shenzhen has a highly advanced and comprehensive industrial chain, which provides a reliable guarantee for Kingsine Electric to develop, produce, and manufacture high-tech, high-quality, and reliable products.
Where am I going?
Philosophy
Adhering to the belief of novelty in technology and detail in service, and gradually establishing a global service and sales network with worldwide partners and distributors, Kingsine shall spare no effort to serve customers worldwide with innovative technology, reliable products, and quality online service, making electric testing easier across the world.
Business Principles
Kingsine's business principle is to create value for customers, which is reflected in three aspects.
Firstly, Kingsine uses advanced technology to create powerful product features that offer customers a great operating experience.
Secondly, Kingsine provides high-quality products and services at reasonable prices, ensuring that customers receive high value for their investment.
Thirdly, Kingsine emphasizes reliability and after-sales service, providing quality assurance through lean production and ensuring that products have over 15 years of service life and three years of warranty. Kingsine's after-sales maintenance principle is based on cost accounting, ensuring that after-sales service remains efficient and affordable.Based on our modular product design philosophy, and with the help of efficient video diagnostics, our target for after-sales maintenance service is to complete repairs within 20 days.