Access Control AC110 / 220V Electric Barrier Gate For Parking System
Advanced Features:
1)clutch key can be used to open the clutch when power off.
2)Fan cooling machine reduce the motor temperature by high frequency using, never get heat-protecting, unique temperature calefaction design for low temperature using, prevent freezing in cold weather.
3)Exactitude aluminium alloy die-casting motor base reduce the noise and joint abrasion to prolong the barrier gate working life.
Model Selection and Differences
Specifications
Model | WST1211 |
Working Temperature | -40℃~+75℃ |
Voltage | 220V±10%, 110V±10%, 50/60HZ |
Rated power | 80W |
Relative humidity | ≤90% |
Remote control distance | ≥30m |
Net weight | 48kgs |
Speed | 1S,1.8S,3S, 6S |
Max boom length | 6 meters |
Motor Rotational speed | 1400rmp |
Protection Degree | IP44 |
Communication with customers
1) Q: Connected power and press open/close button but traffic
barrier gate no action?
A | Reason | Solution |
1 | Fuse blown | Check fuse and power in controller |
2 | Battery of remote control powered off | Change a new one |
3 | External protection circuit break or at protecting status | Open the barrier door and click OPEN/CLOSE button on control box |
4 | Same frequency interference | Check photocell and loop detector |
2) Q:Connected power and press open/close button,traffic barrier
gate will move but even when it is at right position, the motor
still running and not stop?
A | Reason | Solution |
1 | Limit switch | Adjust the horizontal/vertical limit switch to correct position |
2 | Main controller failure | Change a new one |
3) Q: Motor running but traffic barrier gate arm no action?
A | Reason | Solution |
1 | Barrier arm at 45° position where is hard to move | Unlock clutch and manually rotate arm to horizontal or vertical position then try again |
2 | Tension of balancing spring not suitable | Adjust spring exactly |
3 | Low working voltage | Check the voltage and power |
4) Q: When opening/closing,traffic barrier gate arm cannot reach
right position (90° vertical & 180° horizontal)?
A. | Reason | Solution |
1 | Length adjustment of connecting rod not correct | Open barrier door and unlock clutch to check when arm at 90° vertical position if the master rod covers slave one; when arm at 180° horizontal position if master rod and slave one are in the same straight line |
2 | Nuts on the limit switch loose | Tighten the nuts when arm at 90° vertical and 180° horizontal |
1 pcs Gate Barrier
1 pcs arm boom (from 1m to 6m can customised)
1 pcs control panel(built inside)
2 pcs remote controllers
1 pcs manual book
Contact us for pricelist and catalog: