Programmable Corrosion Test Chamber Salt Spray Testing Machine
Product Description:
Salt Spray Chamber adapted to the surface treatment of various materials, including paint, electroplating
organic and inorganic coating, anode processing, antirust oil and so on, after these anti`corrosive treatment to test the corrosion resistance of their products.
Salt Spray Chamber is specially designed for the testing of the corrosion resistance of the products after their material surfaces have been treated with electric plating, anodizing, spray coating, anti-rusting oil and other anti-erosion treatment.
Operation Method
1, the salt spray test chamber internal part: Tower spray
apparatus, funnels, round bars, v-rack installed.
2, connected to the gas source, after the power is switched on,
turn on the power switch.
3, bins and cabinets with water pressure, low water level in two
lights go off after stop adding water, water seal seal groove.
4, purified water and sodium chloride salt is 1:20 with a good
percentage of it. With a good pour solution into the entrance of
the test drug (low salt lamp is off).
5, when all the lights go off, we can open the action, spray, time
switches, turn mist switch until the end of trial.
6, according to the test requirements for equipment and cycle two
spray modes (continuous spray time T1 and T2 tables are all 0,
intermittent spraying time T1 to the working time, T2 for rest
time).
Specification:
Model | HD-E808-60 | HD-E808- 90 | HD-E808-120 | HD-E808-160 | HD-E808-200 |
Work-space volume: | 108L (3.8 cu. ft.) | 270L (9.5 cu. ft.) | 600L (21 cu. ft.) | 800L (28 cu. ft.) | 1440L (50.8 cu. ft.) |
Dimensions | |||||
Workspace dimensions (WxDxH): | 60× 40× 45 cm (23.6" x 15.7" x 17") | 90× 60× 50cm (35" x 23.6" x 19.6") | 120× 100× 50 cm (47" x 39.3" x 19.6") | 160× 100× 50 cm (63" x 39.3" x 19.6") | 200× 120× 60 cm (78.7" x 47" x 23.6") |
Exterior dimensions (WxDxH): | 107× 60× 118 cm (42" x 23.6" x 46") | 141× 88× 128cm (55.5" x 34.6" x 50") | 190× 130× 140 cm (74.8" x 51" x 55") | 230× 130× 140 cm (90.5" x 51" x 55") | 270× 150× 150 cm (106" x 59" x 59") |
Performance | |||||
Temperature Range: | RT+5°C ~55°C (RT+-41°F ~ 131°F) | ||||
Temperature Fluctuation: | ± 0.5° C | ||||
Temperature Gradient: | ± 2° C | ||||
Spray Quantity | 1.0~2.0 ml / 80cm2 / hr | ||||
Power | AC220V, 1Ø ,30A | ||||
Safety Protection | Multiple Safety Protection Devices | ||||
Accessories | Testing Salt/ Measuring tank/ Equipment each 1 set | ||||
Standard | CNS: 3627, 3385, 4159, 7669, 8886; JIS: D0201, H8502, K5400, Z2371; ISO: 3768, 3769, 3770; ASTM: B117, B268, MIL-STD-810F |
Air Pressure Adjustment
a: Inlet pressure adjustment from the first stage regulator
manually, the general control 2 ~ 4kg / cm2
b: spray pressure by the pressure reducing valve adjusted to 0.5 ~
1.7kg / cm2, the Syrian adjustment has been adjusted in the
factory, users generally will not need to adjustment.
Control System
High-precision P.I.D. temperature controller, the error is ± 0.1 ℃,
Fuji, RKC, Honeywell table (optional).
Continuous or periodic spray either.
All circuits are fitted with circuit breakers, all heaters with
electronic and mechanical thermal protection device.
Multiple system protection, safe and reliable. GB/T2423.17-2008
electrical and electronic product environment testing 2nd part:
test methods-test Ka: salt mist
Internal Structure
1, spray device: Tower sprayer, containing glass nozzle, the spray from the tower
tube and then the guide cone dispersed homogeneously dispersed
throughout the test chamber filled interior;
2, spray volume size adjustment: raise conical dispersion spray tower spray amount is increased,
then lowered to reduce the amount of spray;
3, the collector: the exhaust nozzle of a fine mist, settling in free mode, the
built-in one or more surface area of 80cm2 after collecting funnel
cup salt spray, condenses into water flow from the conduit to the
outside of the housing metering cylinder;
4, the heating tank: tank attached to the bottom of the test chamber for holding water
heated to maintain steady temperature test chamber;
5, Shelves: made of steel, a single load of not more than 2kg, such as
dispersion placed to withstand the weight of 10kg or less, racks
lined with two rows of round holes, the rod is placed in the glove
vertical points and 15 degrees, 30 degrees use
Precautions
1, after the end of each test, the switch should open the oil-water
separator, the oil water put the net, and wipe clean.
2, if a long-term test should not saturated the water put the net,
in normal use, should periodically replace the water in the
saturator.
3, not long-term, if re-do the test, and to deal with all the
electrical supply, gas supply system to make a specific system
check, after the failure to prevent the boot.
4, found dirt clogging the nozzle, remove the nozzle promptly with
alcohol, xylene, or 1: 1 hydrochloric acid wash or superfine wire
careful and clear, not damage the wall of the nozzle opening, so as
not to affect the spray quality.
Hai Da Labtester
Haida International Equipment Co., Ltd Company Profile
Haida Headquarter
Haida Facyory
Haida Team